Model 17800B Recovery/Recycling/Recharging Unit
1
Operating
M
anual
Model 17800B/17801B
Recovery/Recycling/Recharging Unit
For Multiple Refrigerants
Vue de la page 0
1 2 3 4 5 6 ... 49 50

Résumé du contenu

Page 1 - Operating

Model 17800B Recovery/Recycling/Recharging Unit1OperatingManualModel 17800B/17801BRecovery/Recycling/Recharging UnitFor Multiple Refrigerants

Page 2 - WARNING

© 2001 Robinair, SPX Corporation10The VacuMaster® vacuum pump is shipped without oil in the reservoir. Beforestarting the unit, you must fill the pum

Page 3 - Introduction

Model 17800B Recovery/Recycling/Recharging Unit11Set Up InstructionsBefore using a new tank, you must purge its nitrogen charge and pull it into a vac

Page 4

© 2001 Robinair, SPX Corporation12Operating InstructionsDiagram of Control PanelRECOVERY PROCEDURESWARNING!Always wear safety goggles when working wi

Page 5

Model 17800B Recovery/Recycling/Recharging Unit13The “CL-L” message shows on the display if there is pressure in the unit, and a self-clearing process

Page 6

© 2001 Robinair, SPX Corporation14Operating InstructionsImportant!Before changingrefrigerant types,be sure the redhigh side and bluelow side hoses ar

Page 7

Model 17800B Recovery/Recycling/Recharging Unit154. If you need to change hoses for the next refrigerant type, go to Step 5. If you donot need to chan

Page 8

© 2001 Robinair, SPX Corporation16Operating InstructionsA/C-R SYSTEM EVACUATIONWARNING!Always wear safety goggles when working with refrigerant. Use

Page 9

Model 17800B Recovery/Recycling/Recharging Unit17RECYCLING PROCEDURESWARNING!Always wear safety goggles when working with refrigerant. Use only autho-

Page 10 - Set Up Instructions

© 2001 Robinair, SPX Corporation18Operating InstructionsCHARGING PROCEDURESWARNING!Always wear safety goggles when working with refrigerant. Use only

Page 11

Model 17800B Recovery/Recycling/Recharging Unit198. Close the high and low side valves on the control panel and start the A/C-R system.Compare the gau

Page 12 - Operating Instructions

© 2001 Robinair, SPX Corporation280S2 WARNINGPRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. OVERFILLING OF THE TANK MAY CAUSE VIOLENT EXPLOSIONAND PO

Page 13 - Weight Example

© 2001 Robinair, SPX Corporation20Operating InstructionsIMPORTANT!When setting upfor new types ofrefrigerant, aclearing processwill have to beperform

Page 14 - AUTOMATIC

Model 17800B Recovery/Recycling/Recharging Unit21Weight Example ** The display shows the weight ofrefrigerant added to the tank.(Adding Refirgerant to

Page 15

© 2001 Robinair, SPX Corporation22This overview is designed as a quick reference when using your unit. Read and follow allwarnings in the operating m

Page 16

Model 17800B Recovery/Recycling/Recharging Unit23The longest time that can be programmed is 98.99 (98 minutes and 99seconds).3. Press VACUUM to start

Page 17

© 2001 Robinair, SPX Corporation24Weight Example*Weight Example**Enter the correctweight for yourapplication.4. Close the high and low side valves an

Page 18 - WARNING!

Model 17800B Recovery/Recycling/Recharging Unit25CHANGING THE VACUUM PUMP OILWhen the vacuum pump has run for a total of 10 hours, the “OIL” message w

Page 19

© 2001 Robinair, SPX Corporation26You should change the filter-drier whenever refrigerant has been recovered from a burn-out system or when the displ

Page 20

Model 17800B Recovery/Recycling/Recharging Unit27Diagram of Filter-DrierMaintenance ProceduresFilter-DrierO-ringOil ReturnManifoldINST0922

Page 21

© 2001 Robinair, SPX Corporation28CONFIRMING THE SCALE CHECKLISTBlank Display or No Warnings.Check wire connections from scale assembly to the circui

Page 22 - Operating Overview

Model 17800B Recovery/Recycling/Recharging Unit29If the scale does not respond to testing, verify that the scale cable is plugged intothe main circuit

Page 23

Model 17800B Recovery/Recycling/Recharging Unit3This manual contains important safety procedures concerning the operation,use and maintenance of this

Page 24 - *Enter the correct

© 2001 Robinair, SPX Corporation30WARNINGUnplug the unit before beginning any service work.Improper use or connections can cause electrical shock. On

Page 25 - Maintenance Procedures

Model 17800B Recovery/Recycling/Recharging Unit31Maintenance Procedures8. Lift the weight form the scale and "HOLD" should appear.NOTE: The

Page 26

© 2001 Robinair, SPX Corporation32CHECKING FOR LEAKSEvery three months, or as specified by local or state laws, you should check your unit forleaks.

Page 27

Model 17800B Recovery/Recycling/Recharging Unit33USING THE CONTROL PANELMAIN POWER Switch — Supplies electrical power to the control panel.Digital Dis

Page 28

© 2001 Robinair, SPX Corporation34KEYPAD FUNCTIONSIn addition to the number keys, the keypad containsspecial keys that accomplish specific operating

Page 29

Model 17800B Recovery/Recycling/Recharging Unit35Segment A — Indicates in which mode the unit is operating:PROGRAM — The unit is in the programming mo

Page 30

© 2001 Robinair, SPX Corporation36to be charged into the A/C-R system; to continue charging, press HOLD/CONT again.RECOVER • With AUTOMATIC, indicat

Page 31

Model 17800B Recovery/Recycling/Recharging Unit37USING THE DIAGNOSTIC MODEThe diagnostic mode allows you to run individual components or retrieve stor

Page 32

© 2001 Robinair, SPX Corporation381. Press “5” to see the complete LCD display, which only displays momentarilybefore returning to the Program mode.

Page 33 - Operating Guidelines

Model 17800B Recovery/Recycling/Recharging Unit39USING DISPLAY CODES134A R-134a; indicates R-134a automotive refrigerantrequiring 1/2” Acme fittings.A

Page 34

© 2001 Robinair, SPX Corporation4The 17800B is a complete A/C-R service center. It recovers, recycles and recharges awide range of refrigerants — fro

Page 35

© 2001 Robinair, SPX Corporation40position. Slide the refrigerant lockout panel (located on the back of the unit, top leftcorner) to expose the fitti

Page 36

Model 17800B Recovery/Recycling/Recharging Unit41Following is a list of replacement parts and accessories you may need toservice or maintain your unit

Page 37

© 2001 Robinair, SPX Corporation42INST0923Flow Diagram

Page 38 - Example of Full Display Test

Model 17800B Recovery/Recycling/Recharging Unit43Wiring DiagramINST0924

Page 39

© 2001 Robinair, SPX Corporation44RECOVERY OPERATIONCompressor does not startProblem: Main power switch is offSolution: Turn on switchProblem: Power

Page 40

Model 17800B Recovery/Recycling/Recharging Unit45Runs but will not shut offProblem: Oil drain valve is openSolution: Close the oil drain valveProblem:

Page 41 - Replacement Parts

© 2001 Robinair, SPX Corporation46RECHARGING OPERATIONNo power when MAIN POWER switch is on — no display showingProblem: Power cord is not plugged in

Page 42 - Flow Diagram

Model 17800B Recovery/Recycling/Recharging Unit47EVACUATION OPERATIONVacuum pump will not startProblem: Power cord is not plugged in or there is no po

Page 43 - Wiring Diagram

© 2001 Robinair, SPX Corporation48This product is warranted to be free from defects in workmanship, materials, and com-ponents for a period of one ye

Page 44 - Troubleshooting

Model 17800B Recovery/Recycling/Recharging Unit49A/C-R System Evacuation 14Adding Refrigerant to the Tank 18Air Purge Gauge, Diagram 15Calibrating the

Page 45

Model 17800B Recovery/Recycling/Recharging Unit5GENERAL OPERATING GUIDELINES• The voltage at the unit must be ±10% of the unit’s rated voltage. Extens

Page 46

© 2001 Robinair, SPX Corporation50124048 (Rev. 5/01) Printed In USACall toll-freeTechnical Support Line800-822-5561in the continental U.S. or Canada.

Page 47

© 2001 Robinair, SPX Corporation6Diagram of Unit’s Components — Internal ViewBefore you begin any procedure, familiarize yourself with the components

Page 48 - Limited Warranty

Model 17800B Recovery/Recycling/Recharging Unit7Diagram of Control Panel and KeypadDiagram of Unit’s Components — Side ViewsINST0918Pressure/Temperatu

Page 49

© 2001 Robinair, SPX Corporation8Before starting the set up procedures, open the system oil drain valve and allow the unitto depressurize.1. Plug the

Page 50 - 800-822-5561

Model 17800B Recovery/Recycling/Recharging Unit9Set Up Instructions5. A new tank comes with a dry nitrogen charge of 5 to 10 psi to keep it clean andd